Kaimosi Friends University Repository

Eyelid and tear-film factors associated with contact lens discomfort symptom burden among wearers attending after-care in Kisumu County, Kenya: a clinic-based crosssectional study

Show simple item record

dc.contributor.author Muga, Seth
dc.contributor.author Elochukwu, Emmanue Okenwa-Vincent
dc.contributor.author Ragot, Alfred
dc.contributor.author -Soler, Isabel Signes
dc.date.accessioned 2026-11-25T07:05:35Z
dc.date.available 2026-11-25T07:05:35Z
dc.date.issued 2026
dc.identifier.citation 1. Nichols JJ, Willcox MD, Bron AJ, Belmonte C, Ciolino JB, Craig JP, et al. The TFOS international workshop on contact lens discomfort: executive sum- mary. Invest Ophthalmol Vis Sci. 2013;54:TFOS7–13. h t t p s : / / d o i . o r g / 1 0 . 1 1 6 7 / i o v s . 1 3 - 1 3 2 1 2. 2. Pucker AD, Tichenor AA. A Review of Contact Lens Dropout. Clin Optom. 2020;12:85–94. https:/ /doi.or g/10.21 47/O PTO.S198637. 3. Dumbleton K, Caffery B, Dogru M, Hickson-Curran S, Kern J, Kojima T, et al. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on epidemiology. Invest Ophthalmol Vis Sci. 2013;54:TFOS20– 36. https:/ /doi.or g/10.11 67/i ovs.13-13125. 4. Koh S. Contact lens wear and dry eye: beyond the known. Asia-Pac J Ophthalmol. 2020;9:498–504. https:/ /doi.or g/10.10 97/A PO.0000000000000329. 5. Papas EB. Contact lens discomfort and associated conditions: Definitions and disambiguation relative to dry eye disease. Contact Lens Anterior Eye. 2026;49:102520. https:/ /doi.or g/10.10 16/j .clae.2025.102520. 6. Read ML, Navascues-Cornago M, Keir N, Maldonado-Codina C, Morgan PB. Monitoring ocular discomfort using a wrist-mounted electronic logger. Contact Lens Anterior Eye. 2020;43:476–83. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 2 0 . 0 2 . 0 1 0. 7. Knop N, Korb DR, Blackie CA, Knop E. The Lid Wiper Contains Goblet Cells and Goblet Cell Crypts for Ocular Surface Lubrication During the Blink. Cornea. 2012;31:668. https:/ /doi.or g/10.10 97/I CO.0b013e31823f8d8c. 8. Lievens CW, Rayborn E. Tribology and the Ocular Surface. Clin Ophthalmol. 2022;16:973–80. https:/ /doi.or g/10.21 47/O PTH.S360293. 9. Pult H, Tosatti SGP, Spencer ND, Asfour J-M, Ebenhoch M, Murphy PJ. Spontaneous Blinking from a Tribological Viewpoint. Ocul Surf. 2015;13:236–49. https:/ /doi.or g/10.10 16/j .jtos.2014.12.004. 10. Sullivan BD, Crews LA, Messmer EM, Foulks GN, Nichols KK, Baenninger P, et al. Correlations between commonly used objective signs and symptoms for the diagnosis of dry eye disease: clinical implications. Acta Ophthalmol (Copenh). 2014;92:161–6. https:/ /doi.or g/10.11 11/a os.12012. 11. Tawfik A, Pistilli M, Maguire MG, Chen Y, Yu Y, Greiner JV, et al. Association of Dry Eye Symptoms and Signs in Patients with Dry Eye Disease. Ophthalmic Epidemiol. 2024;31:274–82. https:/ /doi.or g/10.10 80/0 9286586.2023.2248629. 12. la López-de A, Arroyo-Del Arroyo C, Enríquez-de-Salamanca A, Pinto-Fraga J, López-Miguel A, González-García MJ. The ability of the Contact Lens Dry Eye Questionnaire (CLDEQ)-8 to detect ocular surface alterations in contact lens wearers. Contact Lens Anterior Eye. 2019;42(3):273–7. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 1 8 . 1 1 . 0 1 2. 13. Wolffsohn JS, Benítez-Del-Castillo JM, Loya-Garcia D, Inomata T, Iyer G, Liang L, et al. TFOS DEWS III: Diagnostic Methodology. Am J Ophthalmol. 2025;279:387–450. https:/ /doi.or g/10.10 16/j .ajo.2025.05.033. 14. Dietrich J, Garreis F, Paulsen F. Pathophysiology of Meibomian Glands – An Overview. Ocul Immunol Inflamm. 2021;29:803–10. h t t p s : / / d o i . o r g / 1 0 . 1 0 8 0 / 0 9 2 7 3 9 4 8 . 2 0 2 1 . 1 9 0 5 8 5 6. 15. Narang P, Donthineni PR, D’Souza S, Basu S. Evaporative dry eye disease due to meibomian gland dysfunction: Preferred practice pattern guidelines for diagnosis and treatment. Indian J Ophthalmol. 2023;71:1348. h t t p s : / / d o i . o r g / 1 0 . 4 1 0 3 / I J O . I J O _ 2 8 4 1 _ 2 2. 16. Sheppard JD, Nichols KK. Dry Eye Disease Associated with Meibomian Gland Dysfunction: Focus on Tear Film Characteristics and the Therapeutic Land- scape. Ophthalmol Ther. 2023;12:1397–418. h t t p s : / / d o i . o r g / 1 0 . 1 0 0 7 / s 4 0 1 2 3 - 0 2 3 - 0 0 6 6 9 - 1. 17. Willcox MDP. Tear film, contact lenses and tear biomarkers. Clin Exp Optom. 2019;102:350–63. https:/ /doi.or g/10.11 11/c xo.12918. 18. Willcox MDP, Argüeso P, Georgiev GA, Holopainen JM, Laurie GW, Millar TJ, et al. TFOS DEWS II Tear Film Report. Ocul Surf. 2017;15:366–403. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . j t o s . 2 0 1 7 . 0 3 . 0 0 6 . 19. Craig JP, Nichols KK, Akpek EK, Caffery B, Dua HS, Joo C-K, et al. TFOS DEWS II Definition and Classification Report. Ocul Surf. 2017;15:276–83. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . j t o s . 2 0 1 7 . 0 5 . 0 0 8. 20. Gupta PK, Periman LM, Lain E, Donnenfeld E, Hovanesian J, Kim T, et al. Meibomian Gland Dysfunction: A Dermatological Perspective on Pathogenesis and Treatment Outlook. Clin Ophthalmol. 2021;15:4399–404. h t t p s : / / d o i . o r g / 1 0 . 2 1 4 7 / O P T H . S 3 2 7 4 0 7. 21. Nelson JD, Shimazaki J, Benitez-del-Castillo JM, Craig JP, McCulley JP, Den S, et al. The International Workshop on Meibomian Gland Dysfunction: Report of the Definition and Classification Subcommittee. Invest Ophthalmol Vis Sci. 2011;52:1930–7. https:/ /doi.or g/10.11 67/i ovs.10-6997b. 22. Colak D, Kocabeyoglu S, Karakaya J, Irkec M. Association of ocular surface and meibomian gland alterations with silicone hydrogel contact lens wear. Contact Lens Anterior Eye. 2024;47:102093. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 2 3 . 1 0 2 0 9 3 . 23. Ifrah R, Quevedo L, Gantz L. Topical review of the relationship between contact lens wear and meibomian gland dysfunction. J Optom. 2023;16:12–9. https:/ /doi.or g/10.10 16/j .optom.2022.03.004. 24. Ifrah R, Quevedo L, Hazrati G, Maman S, Mangisto H, Shmuel E, et al. Contact lens wear and follow-up and its association with signs and symptoms of meibomian gland dysfunction. Ophthalmic Physiol Opt. 2024;44:153–67. h t t p s : / / d o i . o r g / 1 0 . 1 1 1 1 / o p o . 1 3 2 4 7. 25. Efron N, Jones L, Bron AJ, Knop E, Arita R, Barabino S, et al. The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Interactions With the Ocular Surface and Adnexa Subcommittee. Invest Ophthalmol Vis Sci. 2013;54:TFOS98–122. https:/ /doi.or g/10.11 67/i ovs.13-13187. 26. Pult H, Riede-Pult BH. Impact of soft contact lenses on lid-parallel conjuncti- val folds. Contact Lens Anterior Eye. 2019;42:415–9. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 1 8 . 1 2 . 0 0 5 . 27. Stapleton F, Stretton S, Papas E, Skotnitsky C, Sweeney DF. Silicone Hydrogel Contact Lenses and the Ocular Surface. Ocul Surf. 2006;4:24–43. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / S 1 5 4 2 - 0 1 2 4 ( 1 2 ) 7 0 2 6 2 - 8. 28. Efron N, Brennan NA, Morgan PB, Wilson T. Lid wiper epitheliopathy. Prog Retin Eye Res. 2016;53:140–74. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . p r e t e y e r e s . 2 0 1 6 . 0 4 . 0 0 4 . 29. Jinagal J, Gupta B, Malhotra C, Jain AK. Lid wiper epitheliopathy: Current knowledge and future directions. J Cornea Ocul Surf. 2023;1:113. h t t p s : / / d o i . o r g / 1 0 . 4 1 0 3 / J C O S . J C O S _ 2 0 _ 2 3. 30. Mickles CV, Harthan JS, Barnett M. Assessment of a Novel Lens Surface Treatment for Scleral Lens Wearers With Dry Eye. Eye Contact Lens. 2021;47:308. https:/ /doi.or g/10.10 97/I CL.0000000000000754. 31. Ramasubramanian D, Hernández-Verdejo JL, López-Alonso JM. Influence of Contact Lens Parameters on Cornea: Biomechanical Analysis. Bioengineering. 2024;11:966. https:/ /doi.or g/10.33 90/b ioengineering11100966. 32. Omali NB, Subbaraman LN, Heynen M, Lada M, Canavan K, Fadli Z, et al. Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers. Contact Lens Anterior Eye. 2021;44:56–61. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 2 0 . 0 5 . 0 0 6 . 33. Janti S, Charanya C, Raja AM, Matheen A, Pandurangan R. Knowledge, attitude, and practice of contact lens users among medical college students in Tamil Nadu. Int J Sci Stud. 2014;2:20–3. h t t p s : / / w w w . i j s s - s n . c o m / u p l o a d s / 2 / 0 / 1 / 5 / 2 0 1 5 3 3 2 1 / i j s s _ s e p _ o a 0 5 _ - _ 2 0 1 4 . p d f . Accessed February 26, 2026. 34. Lwanga SK, Lemeshow S. Sample size determination in health studies: a practical manual. Geneva: World Health Organization; 1991. h t t p s : / / i r i s . w h o . i n t / h a n d l e / 1 0 6 6 5 / 4 0 0 6 2 . Accessed March 28, 2024. 35. Chidi-Egboka NC, Jalbert I, Chen J, Briggs NE, Golebiowski B. Blink Rate Measured In Situ Decreases While Reading From Printed Text or Digital Devices, Regardless of Task Duration, Difficulty, or Viewing Distance. Invest Ophthalmol Vis Sci. 2023;64:14. https:/ /doi.or g/10.11 67/i ovs.64.2.14. 36. Höh H, Schirra F, Kienecker C, Ruprecht KW. Lid-parallel conjunctival folds are a sure diagnostic sign of dry eye. Ophthalmol Z Dtsch Ophthalmol Ges. 1995;92:802–8. 37. Németh J, Fodor E, Lang Z, Kosina-Hagyó K, Berta A, Komár T, et al. Lid-parallel conjunctival folds (LIPCOF) and dry eye: a multicentre study. Br J Ophthalmol. 2012;96:1380–5. https:/ /doi.or g/10.11 36/b jophthalmol-2012-301580. 38. Arita R, Fukuoka S, Morishige N. Meibomian Gland Dysfunction and Contact Lens Discomfort. Eye Contact Lens. 2017;43:17–22. h t t p s : / / d o i . o r g / 1 0 . 1 0 9 7 / I C L . 0 0 0 0 0 0 0 0 0 0 0 0 0 3 5 1. 39. Deng Y, Wang Q, Luo Z, Li S, Wang B, Zhong J, et al. Quantitative analysis of morphological and functional features in Meibography for Meibomian Gland Dysfunction: Diagnosis and Grading. eClinicalMedicine. 2021;40:101132. https:/ /doi.or g/10.10 16/j .eclinm.2021.101132. 40. Liu T, Liu S, Gan M, He Y, Fu H, Xu M. Changes of Dry Eye Parameters Especially Meibomian Gland Functions After Punctal Plugs Insertion in Aqueous-Deficient Dry Eye Patients. Front Med. 2022;9:849700. h t t p s : / / d o i . o r g / 1 0 . 3 3 8 9 / f m e d . 2 0 2 2 . 8 4 9 7 0 0. 41. Xiao J, Adil MY, Olafsson J, Chen X, Utheim ØA, Ræder S, et al. Diagnostic Test Efficacy of Meibomian Gland Morphology and Function. Sci Rep. 2019;9:17345. https:/ /doi.or g/10.10 38/s 41598-019-54013-4. 42. Chalmers RL, Begley CG, Moody K, Hickson-Curran SB. Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and opinion of contact lens performance. Optom Vis Sci Off Publ Am Acad Optom. 2012;89:1435–42. h t t p s : / / d o i . o r g / 1 0 . 1 0 9 7 / O P X . 0 b 0 1 3 e 3 1 8 2 6 9 c 9 0 d. 43. Chalmers RL, Keay L, Hickson-Curran SB, Gleason WJ. Cutoff score and responsiveness of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) in a large daily disposable contact lens registry. Contact Lens Anterior Eye J Br Contact Lens Assoc. 2016;39:342–52. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . c l a e . 2 0 1 6 . 0 4 . 0 0 5. 44. Altman DG, Royston P. The cost of dichotomising continuous variables. BMJ. 2006;332(7549):1080. https: //d oi. or g/10 .11 36/ bmj. 332.7549.1080 en_US
dc.identifier.uri http://erepository.kafuco.ac.ke/123456789/435
dc.description.abstract Background Contact lens discomfort (CLD) is a major cause of reduced wearing time and discontinuation of contact lens wear. However, many wearers continue using contact lenses despite persistent symptoms, and evidence from sub-Saharan Africa on the clinical correlates of symptom burden remains limited. This study examined associations between routinely assessed eyelid and tear-film characteristics and CLD symptom burden among contact lens wearers attending after-care in Kisumu County, Kenya. Methods This clinic-based cross-sectional study included 118 contact lens wearers attending after-care services in Kisumu County. CLD symptom burden was measured using the continuous Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) total score. Univariable and multivariable linear regression models with HC3 heteroscedasticity-robust standard errors estimated mean differences in CLDEQ-8 scores. The adjusted model included age, sex, blink rate, Schirmer’s test, tear breakup time (TBUT), lid-parallel conjunctival folds (LIPCOF; ≥2 vs. 0–1 folds), and meibomian gland function. A sensitivity analysis used the established CLDEQ-8 threshold of ≥ 12 as a binary outcome. Results The mean CLDEQ-8 score was 17.2 (SD 6.3). In univariable analysis, participants with ≥ 2 LIPCOF folds had CLDEQ-8 scores 3.28 points higher than those with 0–1 folds (95% CI 0.94 to 5.62; p = 0.007). The association remained after adjustment (mean difference 2.92 points, 95% CI 0.50 to 5.33; p = 0.018). Blink rate, Schirmer’s test, TBUT, and meibomian gland function showed no clear adjusted associations with symptom burden. Excluding TBUT from en_US
dc.language.iso en_US en_US
dc.publisher BMC Ophthalmology en_US
dc.subject Contact lenses, Contact lens discomfort, CLDEQ-8, Symptom burden, Lid-parallel conjunctival folds, Tear film, Blinking, Kenya en_US
dc.title Eyelid and tear-film factors associated with contact lens discomfort symptom burden among wearers attending after-care in Kisumu County, Kenya: a clinic-based crosssectional study en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Erepository


Browse

My Account